Operation ManualRecirculating Chiller F-100 / F-105 / F-108 / F-11411593721 en
2 Safety10 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E2.6 General safety rulesResponsibility of the operatorThe head of the laboratory
3 Technical data11 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E3 Technical dataThis section introduces the reader to the Recirculating
3 Technical data12 F-100 / F-105 / F-108 / F-114 Operation Manual, Version ETechnical data (115 V)F-100 F-105 F-108 F-114Power consumption (max.) 850
3 Technical data13 F-100 / F-105 / F-108 / F-114 Operation Manual, Version ETechnical data (100 V)F-100 F-105Power consumption (max.) 850 W 850 WSupp
4 Description of function14 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E4 Description of functionThis section explains the basic workin
4 Description of function15 F-100 / F-105 / F-108 / F-114 Operation Manual, Version EDiagram F-105 / F-108 / F-11432145671 Circulation pump2 Containe
5 Putting into operation16 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E5 Putting into operationThis section describes how the instrumen
5 Putting into operation17 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E! WARNINGStumbling or falling due to improper installation of the
5 Putting into operation18 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E5.2 Electrical connections NoticeRisk of instrument damage if ma
6 Operation19 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E6 OperationThis section gives examples of typical instrument applications and
6 Operation20 F-100 / F-105 / F-108 / F-114 Operation Manual, Version ESTOPButton to stop the cooling regulation.Display (not for F-100)13421 Set temp
6 Operation21 F-100 / F-105 / F-108 / F-114 Operation Manual, Version ERear side182756341 Cooling medium flow in2 Cooling medium flow out3 Power sock
6 Operation22 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E6.2.1 Installing the hoses! WARNINGStumbling or falling due to improper instal
6 Operation23 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E6.3 Start operationNOTESee installation instructions (chapter 5.1) for initial
6 Operation24 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E6.5 Working with BUCHI vacuum controllerThe Chiller models F-105 and above are
7 Maintenance and repairs25 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E7 Maintenance and repairsThis section gives instructions on mai
7 Maintenance and repairs26 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E7.2 General inspection and cleaning instructionsCheck the housi
8 Troubleshooting27 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E8 TroubleshootingThis section helps to resume operation after a problem
8 Troubleshooting28 F-100 / F-105 / F-108 / F-114 Operation Manual, Version EMalfunctions and their remediesProblem RemedyF-100 / F-105 does not work
9 Shutdown, storage, transport and disposal29 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E9 Shutdown, storage, transport and disposal!
Table of contents3 F-100 / F-105 / F-108 / F-114 Operation Manual, Version ETable of contents1 About this manual . . . . . . . . . . . . . . . . . .
9 Shutdown, storage, transport and disposal30 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E9.2 Disposal! CAUTIONFreeze-burns and eye inj
9 Shutdown, storage, transport and disposal31 F-100 / F-105 / F-108 / F-114 Operation Manual, Version EHealth and Safety Clearance Health and Safety
10 Spare parts32 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E10 Spare partsThis section lists spare parts, accessories and options incl
10 Spare parts33 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E10.2 Instrument configurationContentInstrument versions: BUCHI Recirculatin
10 Spare parts34 F-100 / F-105 / F-108 / F-114 Operation Manual, Version ETubing, silicone, 6/9 mm, 1m, trans-parent (F-100, F-105, F-108)04133Tubing
10 Spare parts35 F-100 / F-105 / F-108 / F-114 Operation Manual, Version EY piece tubing coupling, 8 mm 011043Y piece tubing coupling, 12 mm 11058358
BÜCHI Labortechnik AGMeierseggstrasse 40CH-9230 Flawil 1 / SwitzerlandT +41 71 394 63 63F +41 71 394 65 65www.buchi.com Quality in your hands
1 About this manual4 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E1 About this manualThis manual describes the Chiller and provides all
2 Safety5 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E2 SafetyThis section introduces the safety concept of the instrument and contains
2 Safety6 F-100 / F-105 / F-108 / F-114 Operation Manual, Version E2.4 Safety warnings and safety signs used in this manualDANGER, WARNING, CAUTION a
2 Safety7 F-100 / F-105 / F-108 / F-114 Operation Manual, Version ESymbol MeaningFire hazardHarmful to life formsHot item, hot surfaceDevice damageInh
2 Safety8 F-100 / F-105 / F-108 / F-114 Operation Manual, Version EAdditional user informationParagraphs starting with NOTE transport helpful informat
2 Safety9 F-100 / F-105 / F-108 / F-114 Operation Manual, Version ESafety messages regarding Refrigerant R134a:! WARNINGDanger of injury and material